Clage-focused technicians — price agreed before any work

Sat – Thu, 8 AM to midnight

29 areas in 10 governorates

عEN

Clage heater faults and fixes

Before you call, there are simple things you can try yourself — these steps are based on the user manual that comes with the heater. If you try them and the problem stays, the fault is internal and needs a technician.

01

Clage heater not heating, or the water is lukewarm

The most common complaint — and most of the time it is not a fault at all: more water is flowing through the tap than the heater can warm, especially in winter when the incoming water is cold.

Try this:

Open the tap a little less and try again. Less flow = hotter water.

If the water stays lukewarm even at low flow, the heating element has a problem and needs a technician.

02

The heater doesn’t reach the temperature you set

If your water pressure is above 3 bar, the heater passes more water than it can heat.

Try this:

Throttle the water at the tap to suit your model’s specification.

If it continues, the technician will set the flow to your model’s exact specification.

03

The heater doesn’t start at all

Either the water flow is below the minimum that switches the heater on, or the inlet and outlet were connected the wrong way round at installation.

Try this:

Open the tap fully and see whether the heater starts.

If it doesn’t, it needs an inspection — and the cause is usually the installation itself.

04

The temperature changes while you’re in the shower

Usually another tap has been opened at the same time, or the mains pressure in your building is unstable.

Try this:

Setting a fixed temperature (38–40°) solves it in most homes.

If the swings continue with no obvious cause, call us.

05

An LED blinking slowly

Nothing to worry about

This isn’t a fault — it is the heater telling you it has reached its maximum heating capacity.

Try this:

Reduce the water flow and the blinking stops.

No technician needed — this is normal behaviour.

06

All the heater’s lights blinking together

The electronics inside the heater have detected a fault.

Try this:

Switch the power to the heater off for a full minute, then back on.

If the blinking comes back, don’t open the heater yourself — call us.

07

An ER or Er Lb code on the display

ER is a general control-system error. Er Lb means air trapped in the pipes — the heater shuts itself down for 60 seconds as protection.

Try this:

With ER: switch the fuse off for a moment and back on. With Er Lb: open the tap a little until the air clears.

If the code keeps coming back, write it down exactly and call — the code tells the technician where the fault is before arriving, so they come with the right part.

08

Clage heater tripping the power (the breaker trips)

Danger — don’t wait

A tripping breaker means a problem with the wiring, the voltage or the cable.

Try this:

Don’t try it yourself more than once.

A technician must check the wiring and voltage before it is switched back on — electricity and water are no joke.

09

Water leaking from the heater body

Danger — don’t wait

A loose connection or internal damage to the body.

Try this:

Shut off the water supply and switch off the power to the heater immediately.

Call us the same day — a leak near electricity is a real hazard, and every hour of delay grows the damage.

10

Heating has become weaker over time

Usually calcium built up from hard water, a heating element starting to wear, or a temperature sensor that needs calibrating.

Try this:

Cleaning the calcium filter every two to three years delays this problem for years.

An accurate diagnosis needs a technician’s inspection.

11

A clicking sound when it starts

Nothing to worry about

Normal in hydraulic models as the valve opens and closes.

Try this:

Nothing — relax.

No action needed.

Tried the fixes and the problem is still there? That means the fault is internal — call us and the technician will come with the part you need. Our Clage repair service in detail

Call 16062

Heater needs a repair? Don’t wait

Small faults grow — call now and we’ll set a time.

16062